The neutral grounding series

WF-XHZ Adjustable Trip Arc Suppression Coil

型号:WF-XHZ

规格:

Description: WF-XHC series load switch Multitap automatic tracking arc suppression coil grounding compensation sets of equipment, the use of on-load switching regulator to achieve equivalent Petersen coil reactance changes. Petersen coil wide tuning range, strong adap


In power system, it is a comprehensive problem that whether generator neutral point grounds or how to ground, refering to technology, economy, safety and so many fields. Usually relative neutral point treatment is adopted according to various operation requirements. In order for safety of people and machine, it is necessary to strengthen research of neutral point treatment of electrical equipments for determining  a good neutral ground model based a safe and economic oepration.

In the case that generator does not ground, when generator stator winding has single-phase grounding fault, grounding fault current would be much lower than load current due to not forming loop short-circuit, which is called small current grounding system. Current flowed throungh grounding point is capacitance current of elements like busline, branch line and low voltage wind of main transformer and so on with which generator connects for drawing forth loop circuit. When excessing allowable value, stator core would be burned and moveover the stator winding insulation would be damaged, causing turn-turn or phase-phase short-circuit. Therefore, we need to take protective measurements like arc-suppression coil or high-resistance grounding to generator neutral point avoiding destroying of generator.   

WF-XHZ arc suppression coil with turns adusts inductive current via switch to shift gear to achieve equivalent reactance variation of arc suppression coil. It could adjust in a large range, good adaptation to system and achieve compensation in 0 second. It is to constitute arc suppression coil ground system by being connected between ground and generator or transformer. The system would generate a inductive current to nuetralize capacitive current in neutral ungrounded system when single phase grounds. By this the ground fault current is controlled in a allowable value of generator, avoiding arc flash from restriking which usually leads to transient ground overvoltage. To generator, the system prevent the stator wire and iron core from burning by large grounding current, enhance reliablity of system by ensuring generator operates with fault and convenient serviceman to clear up the fault.


Counts:2067 Time:2013-05-27 15:58:03【Print】【Back

Copyright © 2013 All Rights Reserved Address: Taipei District seven all the way to the intersection with the East Third Ring Code:071000
Phone:(+86) 312-7517886 Mobile:(+86) 13832277552 Sales hotline:(+86) 13700326805 Fax:(+86) 312-5057520